Main objective: The goal is to to determine the accuracy of Dexcom G7 Continuous glucose monitor system in critically ill patients, undergoing major abdominal surgery and solid organ transplantation, in the intensive care unit. On admission to the intensive care unit or at the end of surgery, two Dexcom G7 sensors are placed in the infraclavicular position. Sensor number 1 will be blinded and will only be active when paired with the receiver, without the ability to monitor glucose levels. Sensor number 2 is used for continuous glucose monitoring and can be used to adjust the insulin dose. Patients will wear the continuous glucose monitoring sensor for a maximum of 10 days, including the time spent in the intensive care unit and the immediate care unit. The study will not interfere with any usual care clinical workflows. Calibration is only performed on an unblinded sensor. The reference method for calibration is the glucose from the blood glucose meter. Calibrate on the first day of monitoring: 4 times a day after approximately 6 hours, or if the blood glucose reading from the blood glucose meter is not within the estimated error range of the continuous glucose monitor (difference greater than 1,5mmol/L). Calibration on days 2 and 3 of monitoring: once in the morning, or when the meter's glucose reading is not within the estimated error range of the continuous glucose monitoring (difference greater than 1,5mmol/L) On subsequent days when the blood glucose meter reading is not within the estimated error range of continuous glucose monitoring (difference greater than 1,5mmol/L). Hypothesis: * Ho: No difference in mean absolute relative difference (MARD) between calibrated and non-calibrated sensors. * Ha: Calibrated sensors have lower mean absolute relative difference (δ = 4%, SD = 5%). Further objectives: To evaluate further aspects regarding the Dexcom G7 continuous glucose monitor system's performance in the intensive care unit (ICU), particularly in terms of sensitivity and specificity to detect hypo- and hyperglycaemic events, data availability, device deficiencies and safety. To identify predictive factors of the accuracy of the Dexcom G7 continuous glucose monitor system in critically ill patients in the ICU.
Age range
18 Years
Sex
ALL
See this in plain English?
AI-rewrites the medical criteria so a patient or caregiver can understand them. Always confirm with the trial site.
Bring these to your next appointment. They're a starting point for a shared conversation — not a sign you qualify or a recommendation to enrol.
Generated to help you prepare — always confirm anything about your own eligibility and care with the study team and your doctor.
The trial coordinator is the person who runs the study day to day. These cover the practical side — logistics, costs, and what taking part would actually mean for your life. The study team confirms whether you meet the criteria; these are questions to ask, not a sign you qualify.
A starting point for the conversation — always confirm anything about your own eligibility, costs, and care with the study team and your doctor.
Calculate overall mean absolute relative difference between arms
Timeframe: From enrolment to discharge from ICU care or up-to day 10