This clinical study will be performed in three phases. The purpose of Phase 1 of this study is to compare the ECG data recorded using the ZywieZ3 Sensor and ZywieZ3 Adhesive ("Test Device") to the data recorded by a traditional 3-lead ECG device that uses wet Ag-AgCl adhesives in a standard lead location ("Reference Device"). The ECG signals will be recorded simultaneously with both ECG devices from the subjects in conditions that represent the devices' intended use for 1 hour. This comparison will determine whether the Test Device recordings are similar to the "gold standard" Reference Device. The testing methodology for this portion of the study is based on guidance provided by the FDA to the Sponsor. The purpose of Phase 2 of this study is to evaluate the ECG signal quality of the Test Device over a 10-day simulated use period by human subjects. This duration of 10 days represents the expected maximum period of usage for the Test Device by the Sponsor. The skin adhesion properties of the Test Device will be evaluated, including a determination of whether any skin reactions, discoloration of the Test Device adhesive (including the snaps and hydrogel), or Test Device adhesive degradation leading to particulate formation occurs over a 10-day simulated use period by human subjects. During this testing, a human factor critical task analysis will be conducted via a collection of observational data regarding success in subject completion of Sponsor-identified critical tasks, subject completion of knowledge questionnaires relating to aspects of Sponsor-identified critical tasks, and subject completion of general subjective questionnaires regarding any difficulty they experienced with use of the Test Device. Testing methodology for this portion of the study is based upon the "Adhesive Performance (Duration of Use)" \[Section 5.4\] procedures from ANSI/AAMI Standard EC12:2000/(R)2020, Disposable ECG Electrodes and the 2016 FDA Guidance for Industry and Food and Drug Administration Staff titled "Applying Human Factors and Usability Engineering to Medical Devices." The purpose of Phase 3 of this clinical study is to assess the effects of variable ECG electrode placement for the ZywieZ3 Sensor and ZywieZ3 Adhesive ("Test Device"). This testing is intended to determine whether ECG electrode placement variability produces unacceptable / non-clinically relevant ECG data and what level of ECG electrode placement variability is acceptable.
Age range
18 Years – 80 Years
Sex
ALL
See this in plain English?
AI-rewrites the medical criteria so a patient or caregiver can understand them. Always confirm with the trial site.
Bring these to your next appointment. They're a starting point for a shared conversation — not a sign you qualify or a recommendation to enrol.
Generated to help you prepare — always confirm anything about your own eligibility and care with the study team and your doctor.
The trial coordinator is the person who runs the study day to day. These cover the practical side — logistics, costs, and what taking part would actually mean for your life. The study team confirms whether you meet the criteria; these are questions to ask, not a sign you qualify.
A starting point for the conversation — always confirm anything about your own eligibility, costs, and care with the study team and your doctor.
Phase 1: Test Device Sensor and Adhesive Equivalence to a Reference Device
Timeframe: From enrollment to end of the 1-hour ECG reading period
Phase 2: Evaluate the ECG signal quality of the Test Device over a 10-day simulated use period by human subjects
Timeframe: From enrollment to 10 days after initial application of the Test Device
Phase 3: Clinical equivalence of ECGs from different electrode placement positions compared to the control position of the Test Device
Timeframe: From enrollment to completion of data collection from all 10 positions performed in a single visit.