The diagnosis of hypertensive disease during pregnancy is predicated on strict blood pressure thresholds: 140/90 on at least two occasions measured four hours apart for both gestational hypertension and preeclampsia. An improvement in diagnostic accuracy of even 5mm Hg would be significant, as reflected by the US Association for the Advancement of Medical Instrumentation (AAMI), the British Hypertension Society, the European Society of Hypertension (ESH) Working Group on Blood Pressure (BP) Monitoring, and the International Organization for Standardization (ISO)consensus for validation of non-invasive blood pressure (NIBP) devices during pregnancy. Given the known inaccuracies of upper arm cylindrical cuff measurements in morbidly obese patients, a conical cuff which provides more accurate measurements will translate into direct patient benefit via more informed diagnosis and management. Fewer women may be exposed to unnecessary treatment, preterm delivery, and/or cesarean section. Recognizing the increasing prevalence of morbid obesity and hypertensive disease amongst pregnant women in the United States, the identification of a more accurate non-invasive cuff is desperately needed. Increasing the accuracy of NIBP measurements on Labor and Delivery has the potential to directly impact the management of tens of thousands of morbidly obese pregnant women diagnosed with hypertensive disease in the United States every year. Establishing the level of agreement between conical forearm and cylindrical upper arm cuffs will shed light on the presence and magnitude of any disparity between measurement methods. STUDY ENDPOINTS: Primary Outcome Measures: * Agreement between conical and cylindrical cuff systolic blood pressure across groups * Agreement between conical and cylindrical cuff diastolic blood pressure across groups Secondary Outcome Measures: • Agreement between conical and cylindrical cuff mean arterial pressure
Age range
18 Years
Sex
FEMALE
See this in plain English?
AI-rewrites the medical criteria so a patient or caregiver can understand them. Always confirm with the trial site.
Bring these to your next appointment. They're a starting point for a shared conversation — not a sign you qualify or a recommendation to enrol.
Generated to help you prepare — always confirm anything about your own eligibility and care with the study team and your doctor.
The trial coordinator is the person who runs the study day to day. These cover the practical side — logistics, costs, and what taking part would actually mean for your life. The study team confirms whether you meet the criteria; these are questions to ask, not a sign you qualify.
A starting point for the conversation — always confirm anything about your own eligibility, costs, and care with the study team and your doctor.
Agreement between conical and cylindrical cuff systolic blood pressure as measured by mean absolute deviance
Timeframe: Through study completion, an average of 1 year
Agreement between conical and cylindrical cuff diastolic blood pressure as measured by mean absolute deviance
Timeframe: Through study completion, an average of 1 year