Efficient inhalational anesthetic delivery requires the use of low-flow air and oxygen to reduce drug waste and minimize workspace contamination and environmental pollution. Currently, excess anesthetic gas is scavenged and removed from the operating room via the hospital ventilation system, where it is released into the atmosphere. CO2 is removed from the anesthesia circuit by the use of CO2 removal systems to prevent re-breathing and potential hypercarbia. Carbon dioxide is currently removed using chemical granulate absorbers (CGAs), which trap CO2 in the granules that are later disposed of when absorption capacity is reached. They require replacement approximately every other day when used in moderate to high volume surgical centres, placing a costly burden on the healthcare system and environment (landfill). One of the more concerning downfalls of using CGAs is the potential for the inhalational anesthetics to react with the granules and potentially produce toxic byproducts known as compounds A-E that are nephrotoxic and neurotoxic and require excess amounts of anesthetic gas to dilute. This excess use of anesthetics gases places a financial burden on the healthcare system and has a detrimental impact on the environment. The vast majority of the gases used are eventually released into the environment with little to no degradation where they accumulate in the troposphere and act as greenhouse gases. DMF Medical has created Memsorb, a new CO2 filtration membrane. Memsorb can remove CO2 from the anesthesia circuit without the use of CGAs, thereby eliminating the potential for toxic byproducts and allowing for significantly lower air and oxygen flow to be used, resulting in less use of inhalational anesthetics. Memsorb uses a polymeric membrane (similar to the ones used in oxygenators for cardiac surgery) that selectively allows CO2 to leave the rebreathing system, while maintaining the inhalational anesthetic in the circuit. The lifespan of Memsorb is at least 12 months, resulting in less particulate waste and a decreased cost to the healthcare system. We wish to evaluate the ability and efficacy of Memsorb in removing CO2 from the anesthesia circuit while maintaining physiologic minute volume ventilation, as compared to the traditional CGAs in a variety of surgical procedures, patient populations, and anesthesia gas flows.
Age range
18 Years
Sex
ALL
See this in plain English?
AI-rewrites the medical criteria so a patient or caregiver can understand them. Always confirm with the trial site.
Bring these to your next appointment. They're a starting point for a shared conversation — not a sign you qualify or a recommendation to enrol.
Generated to help you prepare — always confirm anything about your own eligibility and care with the study team and your doctor.
The trial coordinator is the person who runs the study day to day. These cover the practical side — logistics, costs, and what taking part would actually mean for your life. The study team confirms whether you meet the criteria; these are questions to ask, not a sign you qualify.
A starting point for the conversation — always confirm anything about your own eligibility, costs, and care with the study team and your doctor.
Effectiveness of Memsorb compared to CGA to eliminate CO2
Timeframe: Duration of general anesthesia (up to 12 hours)
Impact of Memsorb, using minimal flow anesthesia (≤ 0.50 L/min), on the amount of inhalational anesthetic (ml) used, compared to standard practice
Timeframe: Duration of general anesthesia (up to 12 hours)
Effectiveness of using Memsorb during ventilation for removal of CO2 in laparoscopic surgeries resulting in high CO2 exposure, compared to CGAs
Timeframe: Duration of general anesthesia (up to 12 hours)