GORE® CARDIOFORM Septal Occluder and Antiplatelet Medical Management for Reduction of Recurrent S⦠(NCT03821129) | Clinical Trial Compass
RecruitingNot Applicable
GOREĀ® CARDIOFORM Septal Occluder and Antiplatelet Medical Management for Reduction of Recurrent Stroke in Patients With Patent Foramen Ovale (PFO): the REDUCE Post Approval Study
United States636 participantsStarted 2019-07-25
Plain-language summary
This study will assess the safety and effectiveness of GOREĀ® CARDIOFORM Septal Occluder in a post approval setting and evaluate the quality of operator education and training and transferability of trial experience to a post-market setting.
Who can participate
Age range18 Years ā 70 Years
SexALL
See this in plain English?
AI-rewrites the medical criteria so a patient or caregiver can understand them. Always confirm with the trial site.
Inclusion Criteria:
* Diagnosed with an ischemic stroke presumed to be an embolic stroke of undetermined source (ESUS) verified by a neurologist within the last 365 days prior to enrollment.
* Presence of Patent Foramen Ovale (PFO), as determined initially by positive bubble study utilizing transesophageal echocardiography (TEE) and/or transcranial Doppler (TCD), demonstrating spontaneous right-to-left shunting or right-to-left shunting during Valsalva maneuver.
* Patient is able to tolerate antiplatelet therapy
* Note: Additional Inclusion Criteria may apply
Exclusion Criteria:
* History of or ongoing atrial fibrillation/flutter
* Other co-morbidities including, but not limited to, mural thrombus, dilated cardiomyopathy, cardiac prosthetics (valves), severe native valve disease (including mitral valve stenosis), severe ventricular wall motion abnormalities, aortic dissection, significant atherosclerosis, vasculitis, pre-existing non-vascular neurologic disorders, pulmonary arteriovenous malformations, prior intracranial hemorrhage, severe disability related to prior stroke, autoimmune disorders that would increase the risk of stroke or thromboembolism, or associated with increased risk of infection or procedural complications, in the opinion of the investigator, left ventricular ejection fraction of \<40%, coexistent cause or intra-cardiac shunting (e.g. VSD or ASD)
* Previous Myocardial Infarction
* Rankin Scale sore greater than or equal to 3 at the time of procedure
* ā¦
What they're measuring
1
Proportion of subjects with recurrent ischemic stroke post study device implant (Primary Effectiveness Outcome)
Timeframe: 24 months
2
Proportion of subjects with device- or procedure-related serious adverse events at 30 days (Primary Safety Endpoint)