The purpose of this study is to determine the sensitivity of a wearable sensor to detect changes in knee joint loading using an experimental knee joint effusion as a model for a common clinical physiological alteration in joint status. The rationale for this project is that it will establish the efficacy of an inexpensive, clinically, and publicly available device that can detect changes in biomechanical loading due to acute physiologic change in joint status. The study will utilize a cross-sectional cohort study design and will seek to enroll 25 male and female healthy adult participants (18-35 yo). Participants will report to the laboratory for three total sessions (Session 1: informed consent and task familiarization; Session 2: testing; Session 3: knee joint status assessment). The primary outcomes of interest include lower extremity thigh and shank acceleration and velocity data (wearable sensor data), lower extermity 3D kinematics and kinetics (motion capture data), and lower extremity muscle function (EMG data) during walking gait, as well as functional balance and patient-reported subjective outcomes. Data will be analyzed by calculating change scores from the pre- to post-experimental effusion outcome measure testing. Paired-samples t-tests and Cohen's d effect sizes will be used to assess changed in wearable sensor data from pre- to post-experimental effusion. Correlation statistics will be used to determine if there are association between the motion capture and wearable sensor data. The potential risks associated with an experimental joint effusion will be addressed by maintaining appropriate sterile conditions and having the participant check-in with the PI (licensed healthcare provider) at 48 hours following testing session.
See this in plain English?
AI-rewrites the medical criteria so a patient or caregiver can understand them. Always confirm with the trial site.
Change in Peak Vertical Ground Reaction Force
Timeframe: Immediately Pre- (10 minutes) and Post- (10 minutes) Effusion
Change in Peak Internal Knee Extension Moment
Timeframe: Immediately Pre- (10 minutes) and Post- (10 minutes) Effusion
Change in Peak Knee Power
Timeframe: Immediately Pre- (10 minutes) and Post- (10 minutes) Effusion
Change in Shank Acceleration
Timeframe: Immediately Pre- (10 minutes) and Post- (10 minutes) Effusion
Change in Thigh Acceleration
Timeframe: Immediately Pre- (10 minutes) and Post- (10 minutes) Effusion
Change in Shank Angular Velocity
Timeframe: Immediately Pre- (10 minutes) and Post- (10 minutes) Effusion
Change in Thigh Angular Velocity
Timeframe: Immediately Pre- (10 minutes) and Post- (10 minutes) Effusion